Ошибка, код ошибки: принтеры Oki B6200, Oki B6300Коды ошибок принтеров Oki B6200, B6300
Коды ошибок принтеров Oki B6200/B6300
Коды ошибок принтеров Oki B6200/B6300

Начало таблицы кодов Oki B6200, Oki B6300

Цифры, которые образуют код, значатся в столбиках A и B: если принтер показывает ошибку 006-335, то это означает "Poor ROS MOT rotation" - подклинивает мотор привода призмы.


ABНеисправностьПричинаПримечание
 Fujiko-ODA The true disposal method is indicated as a machine. -- Especially a different portion from the disposal method of a former machine is. system fail/sub system fail (I have a person in charge indicate Fail which requires hard / mechanism part exchange)Fujiko-ODA True detection conditions are indicated as a machine. -- Especially the portion the detection conditions of a former machine are indicated to be as they are is. It is cautious of system fail/sub system fail
008153(IOT JAM) Feed Jam 1 (Early Feed Jam )
The paper arrival to a Reg position is too early
Needlessness The paper arrival to a Reg position is too early
008155(IOT JAM) Regi Sensor On Jam
Reg Sensor is in On state in Warming up
 
008156(IOT JAM) Regi Sensor Off Jam
A paper does not come for a Fuser position from a Reg position within regulation time
 
008176Tray 1 Regi Sensor On Jam
Imari: REGI SNR ON JAM (Tray)
GINGA: Tray1 Missfeed Jam
The same as that of user disposalEven if it carries out regulation time progress from a Tray1 Feed start, a Reg sensor does not turn on

Sensor of IOT Sub detects only by one. Although a display is different for every tray, this will display for the Jam Zone information sent apart from Chain Link.
(Imari: Jam detection specifications K4) No.2 / Regi Sensor On Jam / Feed Tray#1-4
008180Comm: Duplex In Sensor On Jam
(C6-1) Dup Miss Feed Jam
Duplex In Sensor is not turned on in Duplex conveyance operation

Since the timer of operation from a sensor changes with paper sizes at the time of Duplex Module printing, there is two kinds of REGI SENSOR ON JAM.
(Imari: Jam detection specifications K4) No.2 / Regi Sensor On Jam/ DUP
008314Between DCSYS-DM Duplex Unit was separated after the I/F unusual power supply injection Duplex Unit Fail was detected
009413Toner Black 1 Near EmptyThe same as that of user disposalWhen Dispense Motor of Black becomes circumference sky of regulation time closely

Toner Status
* HID 980420   *HID 980430
009460Toner Black Quality Life End (only display)NeedlessnessCRU life operation was set up for not stopping by the panel, and after IOT detected Toner Warning, data transmission was performed by 100 sheets
009670New Toner Detected - K  
009671New Toner Detected - C
009672New Toner Detected - M
009673New Toner Detected - Y
009909Topo: EP Cartridge Type MissmatchThe same as that of user disposalUnentered
009910Topo: EP Cartridge Not Installed
009938GINGA: Black Toner Cartridge DetachedWhen K toner cartridge is not set

030606 Delete from Comm (Fu/Ta/Sh)
010105Fuser Exit Sensor On Jam
Imari: F/U EXIT SNR ON JAM (at the time of F/U discharge)
GINGA: Exit In Jam
Ginga: After RegRoll turns on, even if it carries out regulation time progress, an Exit sensor does not turn on

With no "Imari: Jam detection specifications K4" correspondence
010106
010112GINGA: Exit Out Early JamGinga: After an Exit sensor turns on, an Exit sensor does not turn off within regulation time
010128Duplex Pre Regi Sensor On JamTopo: The paper arrival to a Reg position from a Duplex Sensor position is too early
010132Duplex Path 1 Sensor On JamA paper is not discharged from a Duplex Sensor position within regulation time, or Duplex Sensor is in On state in Warming up
010164Regi.SNR On Jam (C6-2) "Dup Miss Feed Jam" (not wait)Topo: A paper does not come for a Reg position from a Duplex Sensor position within regulation time
sheeta: Duplex Out Sensor is not turned on in Duplex conveyance operation
010347"OCT failure": Offset Fail (OCT) Failure detection / wearing detection cannot be carried out in the "Imari" present condition
010398Fuser Fan Fail (U4-9)If not repaired in power supply OFF/ON, it is FUSER Fan exchangeThe logical sum OR of a FUSER FAN lock signal and a LVFAN lock signal is taken, and it considers as a FAN LOCK FAIL signal
Ginga: When Fuser FAN does not turn at regular number of rotations

Discharge and Billing all the papers that have already Feed(ed)
010420Fuser ASSY Change Soon
GINGA: Fuser Unit Pre Warning
The same as that of user disposalWhen PV reached the regulation value and becomes a life closely
011108OCT Jam 1 (paper attainment is not carried out at OCT)[ from an Exit Sensor position / to an OCT Sensor position / in a paper ] within regulation time
011109OCT Jam 2 (paper attainment is not carried out at OCT)A paper is not discharged from an OCT Sensor position within regulation time, or OCT Sensor is On state in Engine Warming up
012300Faceup Tray was opened during printing When Cover Interlock Open of FaceUpTray was detected in JOB, Faceup Tray was opened during printing in Standard mode or OCT mode
012301Faceup Tray was closed during printing Faceup Tray was closed during printing by Faceup Tray
012951OCT_FULL_STACK Full Stack (OCT) was detected
012952FaceUP Tray OpenAlthough the output to Facedown Tray or OCT was specified, it detected that Faceup Tray was open
012953FaceUP Tray CloseAlthough the output to Faceup Tray was specified, it detected that Faceup Tray had closed
012965FIN STAPLER PIN NEAR EMPTY
Imari: Stapler Near Empty
GINGA: Stapler Near Empty
Topo: Stapler Near Empty
Low Staple Sensor OFFWhen ON of Low Staple Sensor is detected at the time of - power supply injection and Interlock Close in one of the following cases and ON of Low Staple Sensor is detected just before - Staple Head Close operation implementation
012969IOT Center Tray FullH-Tra IOT   Full Paper Sensor continues and it is between 1sec(s) OFFH-Tra IOT   When Full Paper Sensor detects ON by continuation between 10sec(s)

Since a Center tray turns into a tray different from a base when Light Finisher is attached, 7-969 assigns a code independently
016450SMB host name duplicationA host name is changedPC which has the same host name existed on the network
016452IP address duplicationAn IP address is changedPC which has the same IP address existed on the network
016453IP address acquisition failure from a DHCP serverAn IP address is set up (the acquisition from a DHCP server is not performed)IP address acquisition went wrong from the DHCP server
016454Renewal of Dynamic DNS-dynamic goes wrongNeedlessnessNeedlessness
016460A FULL state is detected at the time of HD access. The error of which FULL is canceled also for the waiting for time  
016500SMTP Server Address Resolution Fail for Mail IO- 
016501POP Server Address Resolution Fail for Mail IO- 
016502POP Authentication Fail for Mail IO- 
016503SMTP Server Address Resolution Fail for Redirector- 
016504POP Server Address Resolution Fail for Redirector- 
016505POP Authentication Fail for Redirector- 
016701A PLW deconstructivism memory is insufficientImari: Since a PLW memory is fixation, if it can lower resolution, it will be loweredThe shortage of a memory was detected at the time of ART EX use

Imari: The memory for "print log" PLW processing of a job is insufficient
0167021 page was uncompressibleA memory is extended, resolution is lowered or it is made printing guarantee mode (printing guarantee mode -- PLW) in PCL, "a PCL heap memory / band buffer ratio" is made 1:2 or more setup (Chainlink 801-916 of "O2AP")Shortage of the print page buffer which has not been compressed 1 page was detected
016703Un-establishing and the invalid confidential box number were specified at the time of E-Mail reception1. Establish an E-mail transmitting
2. Relevance box to effective box
At the time of E-mail reception, un-establishing and an invalid confidential box state are detected, and a job end is carried out
016704Confidential box full (the number of the maximum documents was exceeded around one box) is detected, and a job end is carried outAn unnecessary document is deleted and processing is performed againAt the time of HD access, a FULL state is detected and a job end is carried out
016705Security accumulation cannot be carried out without HDIt checks whether it has equipped with HDD.
When a trouble occurs at the time of wearing, it checks whether operation of a security print is wrong
Security accumulation could not be carried out without HDD, but registration of a security print went wrong
016706The job end of having exceeded confidential and the number of the maximum users of a proof print is detected and carried outUnnecessary document/user are deleted and it is execution of a re-printAt the time of HD access, a FULL state is detected and a job end is carried out
016707A proof print is impossible (conditions in which a proof print is possible, such as HD-less/HD failure, do not gather)It checks whether it has equipped with HDD
When a trouble occurs at the time of wearing, it checks whether operation of a proof print is wrong
You could not accumulate without HDD but registration of a proof print went wrong
016709PLW Command Error
An error is detected by PLW deconstructivism
Job is canceled and it performs againThe ART EX command error occurred during PLW processing
016710Delayed Print Fail  
016716The file which carries out a spool by the "TIFF file injustice" TIFF exceeded disk capacityWith no necessity 
016719A PCL deconstructivism memory is insufficientPCL memory size is increasedThe shortage of a memory is detected at the time of PCL use
016720PCL Command Error
An error is detected by PCL deconstructivism
Job is canceled and it performs againA PCL command error occurs during PCL processing
016721Other errorsI have the same job performed again, the state of an error is checked, and it looks for support of Support GThe error which is not expected during print processing
016726A "automatic judging error" Auto SW automatic judging was not able to be carried outFixed selection of the Decomposer is carried outPrint language automatic judging error
016728Tag which is not mounted in a "TIFF file injustice" picture file deployment library is included- 
016729The number of "TIFF file injustice" colors and the number of pixels were specified exceeding the maximum of the effective range- 
016730"ART command error" The command which is not supported by ART was detectedA non-supporting command is deleted and re-printed out of dataART IV command error

Although the "gtemul" command is a command of the meaning of "changing to the print mode of an option cartridge", in multi-PDL, a print language change cannot do it
Error log needlessness "print log" ART command error. Processing was stopped
016731"TIFF file injustice" TIFF data is way piece by the middle- 
016732"Form composition error" In emulation, when the specified form is not registered, the data itself is not printed-Deconstructivism detects that the specified form is not registered
016744It is contained in PDF to which the function which is not supported was sentA visitor is requested to have you print via a driver from Acrobat ReaderIn PDF1.3, Transparency or JBIG2 was contained in the PDF file
016748At the time of confidential box access, a FULL state is detected and a job end is carried outThe capacity of HDD is vacated and it is execution of a re-printAt the time of HD access, a FULL state is detected and a job end is carried out

In Print Job, since the job end only of a part to have been stored in HD is printed and carried out, what is defined as "un-giving a definition / Job Fail" is used
In Copy Job, since a message is displayed and it waits for user directions, what is defined as "Others/Notice" (3-981) is used
Description of the "Fault item" sequence is united above and corrected
016749The syntax error of a "JCL/PJL syntax error" JCL/PJL command was detectedA command is correctedThe syntax error of a JCL/PJL command was detected
016751PDF ErrorThe same as that of user disposalWhen a syntax error, use of the command non-given a definition, a parameter error, breakage of a PDF file, and the internal error of PDF deconstructivism occur during PDF Bridge processing
016752PDF Short of MemoryThe shortage of a memory was detected during PDF Bridge processing
016753PDF Password MismatchedPassword protection is carried out. When the password of UI panel setup and the password specified by XPJL (it sets up by Contents Bridge) are not in agreement by the case where a PDF file is processed
016754PDF LZW Not InstalledLZW compression technology was used in the state where the "Contents Bridge extension kit" is not installed. PDF file processed by PDF Bridge
016755PDF Print ProhibitedPrinting prohibition specification was carried out when a PDF file is processed
016757Auditron - Invalid User 
016758Auditron - Disabled Function 
016759Auditron - Reached Limit 
016760The error occurred in "PS Decompose error" deconstructivism pause processingA job is broadcast again (the check of execution environment / data is required at the time of a recurrence)The error occurred in deconstructivism pause processing
016761"Image output" FIFO EMPTY errorIt prints in speed priority mode. When this cannot be printed, either, it prints in printing guarantee modePicture extension error (FIFO EMPTY error)
016762"Decomposer absence" The functions (a print language, print utility etc.) which are not mounted were required (decomposer specified in PJL or Auto SW is not mounted)Fixed selection of the Decomposer is carried outThe functions (a print language, print utility etc.) by which print language non-carrying mounting is not carried out were required (decomposer specified in PJL or Auto SW is not mounted)
016764SMTP server connection errorNeedlessnessSMTP-server response code: 421 or 451

"Result code" of an error log character sequence is prescribed by RFC
016765SMTP server HD fullThe same as that of user disposalSMTP-server response code: 452
016766The problem of an SMTP server file systemSMTP-server response code: 552
016767E-mail address address injusticeSMTP-server response code: 550 or 551
016768Transmitting agency address injustice (login error)It error-answers by the "MAIL FROM:" command of an SMTP protocol
016769An SMTP server un-corresponds to DSNResponse code of the "EHLO" command of an ESMTP protocol: There is "no DSN" in the support command list received from 502 or the server
016781Server connection is not made at the time of "network connection error at time of network scan" transmission1. Main part From 2. transmission place server which sets up correctly a "subnet mask" and a "gateway" "ping" etc. 3.Win 95 which checks that M/C can be seen From a UNIX machine to a transmission place server It checks that it is connectable by ftpConnection establishment with a FTP server goes wrong
016796Control of mail printing by user setup Imari-MF PL2/AP or subsequent ones
In E-mail reception, since the mail which does not have an appending document in the state of a setup of "not printing a header and the text" was received, mail was canceled
In the case of the above-mentioned case, it leaves Mail IO to the purport and error history report which canceled mail at ChainLink
A mounting top job is not generated
016797Output place injustice of reception mail-It is after change Imari-MF PL2/AP to 127 - 027
Job is not generated
E-mail to Box and E-mail to Fax drop(ed). When E-mail is received by this specification
016798No TrustMarking Option-When Decomposer call(ed) S-Image lib, the error without HD came on the contrary
016799Print Instruction Fail detected in PLW When a print parameter error (003-747) is found by PLW
016981A FULL state is detected at the time of HD access. The error of which FULL is not canceled for the waiting for time, either finishing [ 1 page or more accumulation ]HDD partition size of the service which corresponds if nonavoidable with user disposal is made large 
016982A FULL state is detected at the time of HD access. The error of which FULL is not canceled for the waiting for time, either (1 page cannot be accumulated)HDD partition size of the corresponding service is made largeWhen HDD is judged to be full by the job, the precedence accumulation job, and the interruption job